PEER Shake Table Facility 20 ft x 20 ft table size Still the largest 6 DOF shake table in the US Can test structures, weighing 100,000 lbs, to horizontal accelerations of 1.5 g +/- 5 in. horizontal displacement capacity +/- 2 in. vertical displacement capacity +/- 40 in./sec velocity capacity . 23
Get PriceMay 12, 2018 PEER Shake Table Facility 20 ft x 20 ft table size Still the largest 6 DOF shake table in the US Can test structures, weighing 100,000 lbs, to horizontal accelerations of 1.5 g +/- 5 in. horizontal displacement capacity +/- 2 in. vertical displacement capacity +/- 40 in./sec velocity capacity 38
Get PriceMotivation Many structures exhibit significant rate of loading effects Need testing to occur at or near real time Large systems such as tall buildings, long- span bridges, or SFSI are difficult to test on shake tables Shaking Table Numerical Model Hybrid Shake Table Shaking Table Numerical Model
Get PriceDec 15, 2015 In addition to hybrid simulation capability that can imitate equipment's interaction with its support structure, the real-time hybrid simulation platform described earlier is a high-performance long-stroke uniaxial shake table. When it is used in a shake table configuration, the test response spectrum envelops the IEEE693 High Performance Level
Get PriceJun 21, 2018 A full-scale 5-story steel moment frame building was subjected to a series of earthquake excitations using the E-Defense shake table in August, 2011. For one of the test configurations, the building was seismically isolated by a hybrid system of lead-rubber bearings and low friction roller bearings known as cross-linear bearings, and was
Get PriceThis paper reports the design and a shake table test of timber frame-reinforced concrete (RC) core hybrid systems. Three specimens (S1, S2, and S3) are tested: S1 and S2 are both one-story
Get PriceApr 10, 2019 2.3.3. Research on Hybrid Test Technology of Shaking Table. To solve the limit bearing capacity of shaking table for large structure test, scholars from all over the world conducted a wide variety of researches. The combination of substructure technique and shaking table test is an effective way to solve this problem . Hybrid vibration test
Get PriceShake table testing is often used in prototype analysis, failure analysis, shipping vibration testing and vibration sensitivity testing. We know what boundary conditions are vital for effective testing, how and where to instrument the system, how to deal with off-axis excitation (often not accounted for), and make the most efficient use of testing time
Get Pricea substructure for the shake table test and that for numerical computation, the test method based on this concept is referred to as the SHST Test (Substructure Hybrid Shake Table Test) in the present paper. The experimental aspect is similar to the conventional shake table test since a
Get PriceAug 07, 2020 The control strategy of shaking tables, such as the tri-variable control method, is quite different from the control method of a single actuator often used in real-time hybrid test, further hindering the development of STST. The knowledge accumulated from real-time hybrid test may not be directly applicable in STST
Get PriceDuring the shake table tests, the hybrid structure performed quite well with visual damage only to wood shear walls. No visual damage in SMRFs and the frame-to-wall connections was observed
Get PriceThe proposed hybrid loading test method using a shake table and a hydraulic actuator is intended for the application such as evaluation of real-time dynamic response of structural systems under strong seismic excitation. The test method consists of the shaking table test, and dynamic loading test using a dynamic actuator for the specimens that are parts of the structural system considered and
Get Price10NCEE (2014): Development of a Large Scale Hybrid Shake Table and Application to Testing a Friction Slider Isolated System (Schellenberg, Becker, Mahin) [email protected] (2014): Hybrid Shake Table Test of a Midlevel Seismic Isolated Structure (Schellenberg, Becker, Mahin)
Get PriceJan 01, 2017 This paper reports the design and a shake table test of timber frame–reinforced concrete (RC) core hybrid systems. Three specimens (S1, S2, and S3) are tested: S1 and S2 are both one-story buildings with a nailed plywood floor (flexible diaphragm)
Get PriceMay 03, 2018 This paper present a real-time hybrid substructuring (RTHS) shake table test to evaluate the seismic performance of a base isolated building. Significant experimental research has been conducted on base isolators and dampers toward developing high fidelity numerical models
Get PriceDec 10, 2011 HYBRID SHAKE TABLE AND APPLICATION TO TESTING A FRICTION SLIDER ISOLATED SYSTEM A. Schellenberg1, T. C. Becker2 and S. A. Mahin3 ABSTRACT A unidirectional hybrid control shake table was constructed at the NEES lab at the University of California Berkeley. The 2 m by 6 m table is controlled using an MTS 493 Real-Time Controller
Get Price